QuickTake 30 BioStage Pump

QuickTake 30 (with programmable timer) Sample Pump with Li-Ion battery pack and cassette/tubing adapter, charger not included
Flow range: constant flow 10 to 30 L/min
Ideal for use with BioStage® impactor, VersaTrap® cassettes, Air-O-Cell cassettes, WallCheck II, or impaction samplers that require flows to 30 L/min

Download Brochure

Performance Profile

Flow Range
10 to 30 L/min
Flow Compensation Accuracy
± 5% of set flow

Compensating Flow Back Pressure Range

 

10 L/min at 90 inches water back pressure
20 L/min at 50 inches water back pressure
30 L/min at 15 inches water back pressure
Typical Back Pressure of Sampling Media (inches water)
Flow Rate L/min
10
12
15
20
Filter/Pore Size (µm)
25-mm MCE/0.8
65
80
103
148
25-mm MCE/0.45
138
172
> 200
37-mm MCE/0.8
22
28
36
51
37-mm PVC/5.0
9
11
15
21
Compare the information in this table to compensation range to determine appropriate applications.
Power
Rechargeable lithium-ion (Li-Ion) battery, 7.4-volt, 10.4-Ah capacity, 77 Wh, or battery with AC charger/adapter (100-240 V)
Battery Recharge Time
(varies with battery capacity and level of discharge)
Approximately 5 hrs with approved charger
Typical Cumulative Run Time‡
Spore Trap cassettes (VersaTrap): 5 hrs at 15 L/min (battery only)
BioStage viable cascade impactor: 4 hrs at 28.3 L/min (battery only)
25-mm, 1.2-µm MCE filter: 9+ hrs at 10 L/min
To achieve, use QuickTake 30 with a fully charged battery and AC charger/adapter.
37-mm, 0.8-µm MCE filter: 14+ hrs at 10 L/min (battery only)Note: The AC charger/adapter can be used to extend battery run time, but it is not a battery eliminator. Therefore, it will not provide indefinite run times.
Temperature
Operating: 32 to 104 F (0 to 40 C)
Storage: -4 to 95 F (-20 to 35 C)
Charging:
 32 to 113 F (0 to 45 C)
Operating Humidity 0 to 95% non-condensing
Run Time Features
User-selectable features, user-adjustable presets. See Operating Instructions.
Preset timed runs: 1, 2, 5, 10, or 15 min
Manually set continuous run with manual shut-off: 1 to 999 min (repeats 1 to 999-min runs indefinitely until user stops pump or power supply is depleted)
Intermittent sampling:
 User-set sample periods and sample delays. See Operating Instructions.
Flow Fault Features
If the pump is unable to compensate due to excessive back pressure, the pump will go into flow fault mode. Flow fault features are enabled as the default setting. Flow fault may be disabled at the user’s option. See Operating Instructions.
Flow fault: Flow fault displays immediately. Pump shuts off after 5 seconds.
Fault restart: Pump attempts restart every 10 seconds up to five times.
Media Compatibility
BioStage viable cascade impactor, VersaTrap spore trap cassettes, microvacuum cassettes, and other samplers that require flows to 30 L/min
Tubing
Requires 3/8-inch ID tubing
Housing
ABS plastic
Dimensions
8.4 x 9.3 x 3.5 in (21.3 x 23.6 x 8.9 cm)
Weight
4.8 lbs (2.2 kg)
Noise Level Average < 64 dBA at 3 feet (37-mm, 0.8-µm MCE filter at 16.8 L/min)
Results are obtained using a new pump and new fully charged battery. Pump and battery performance may vary.
Scroll to Top