Konsultasi Lingkungan, Kesehatan dan Keselamatan Kerja (OHS) Perusahaan Distributor/Agen Peralatan Industrial Hygiene Lingkungan Food Safety & Hygiene Setifikasi Kompetensi Personil Lingkungan K3 Kalibrasi Instrument

Alat Uji Emisi Bensin Gasboard 5020

Features

  • NDIR gas bench with regulated temperature system, high accuracy, better stability.
  • Equivalent with OIML R99 class 0 standard.
  • Cleanable NDIR gas chamber for easy maintenance.
  • Built-in printer can print out real time measurement data.
  • The engine tachometer can be connected with Gasboard-5020 by RS-232 communication.
  • Mass production ensures fast delivery.
Gasboard-5020

Gasboard-5020 emission gas analyzer is designed for measuring the emissions of all gasoline, LPG or CNG vehicles, it is developed based on dual beam non-dispersion infrared (NDIR) principle to measure CO, CO2, HC, and electrochemical sensors to measure O2 and NO. The test reports can be printed on the built-in printer. Gasboard-5020 is equivalent with OIML R99 class 0 standard, very suitable for cars, motorcycles, and other light duty, heavy duty vehicles exhaust inspection and then optimize it.

Functions:

– CO, CO2, HC, O2, NO gases measurements

– LCD Screen

– Built-in printer

– Magnetic and battery type RPM sensors

Measurements CO2, CO, HC, optional O2, NOx gases.
Technology NDIR ECD
Measuring range CO2 CO HC O2 NO
0–20% 0–10%
(*0–15% optional)
0–9999 ppm
(*0–20000 ppm optional)
0–25% 0–5000 ppm
Resolution 0.01% 0.01% 1 ppm 0.01% 1 ppm
Error rel. ±4% ±3% ±5% ±3% ±4%
(which ever is greater) Abs. ±0.4% ±0.03% ±10 ppm ±0.1% ±25 ppm
Warm-up time 10 minutes
Response time (T90) 10 seconds (NDIR), 30 seconds (Zirconia)
Display LCD display
Power supply 110V–220V ±10%, 50Hz ±1Hz
Operation Temperature 0–50℃
Dimension 260 × 180 × 360 mm
Flow rate 0.7–1.2 L/min
Weight 6 kg
Standard accessories Sampling pipe and probe, standby filters, RS-232 cable, power cable
Options Built-in printer, RPM sensor, Oil temperature sensor
Scroll to Top